<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-27 21-40-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 60 dBuV YLEX
Pilot RDS Phase Difference
7.1 kHz 2.1 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 63 kHz 19077 4,1568
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,1 dBr 5,55 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 21:40, 27.08.2025
RT
"Rony Rex "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 63 kHz MIN: 12 kHz % above 76 kHz: 4,1568 Acquired: 2025/08/27 21.39.53 Total samples: 19077 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,0 dBr MIN: 5,1 dBr AVE: 5,55 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/08/27 21.39.52) 21.26 21.28 21.30 21.32 21.34 21.36 21.38 0 2 4 6 Pm [dBr]